<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>22273</ErrorNumber>
<ErrorFamily>Autoloader 2</ErrorFamily>
<ErrorMessage>
ALE2: Pcups failed to lift plate
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_VLF_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Pcups failed to lift plate. This is determined by the picker pressure.
The picker system pressure with the pcups down on the plate is recorded
with known air users on, then the pressure is checked again after lifting
pcups (with the same air users active). If the pressure (at the picker) has
dropped by more than 1.7 psi, then it tries again, up to 3 times. The
pressure will rise by about 1 psi if the plate remains on the pcups.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Resume.  If it fails again, cancel the job, open the bay and check that
the back stop and side guids of the plate stack are properly installed.
They should not be too tight (about 1/8" or 3mm clearance)
</text></DescriptionText>
</OperatorAction>
<Cause>
Small plates or thin portrait plates may be sliding over the back stop.
Obtain back stop with top lip.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/Picker.xml</LinkAddress><LinkTitle>Command: Picker</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:34:02 2008 PST